HGL36100CU44X Square D PowerPact H 100A 3-Pole 600V Breaker — MicroLogic 6.2A LSIG, 100% Rated
HGL36100CU44X Square D PowerPact H 100A 3-Pole 600V Breaker — MicroLogic 6.2A LSIG, 100% Rated
Out of stock
Couldn't load pickup availability
HGL36100CU44X Square D PowerPact H 100A 3-Pole 600V Breaker — MicroLogic 6.2A LSIG, 100% Rated
Need a 100A, 3-pole PowerPact H breaker with electronic trip? The HGL36100CU44X is the one. It mounts as a unit breaker with mechanical lugs on both line and load, so it drops straight into your switchboard or panelboard, and it's rated for reverse-fed setups when you need them. The MicroLogic 6.2A trip unit gives you full LSIG — long-time, short-time, instantaneous, and ground fault — plus an ammeter right on the breaker so you can read load current without pulling a meter.
Because it's a 100%-rated breaker, you can run it at full nameplate continuously — no 80% derate to work around when you're sizing the feeder. Interrupting capacity is G-tier: 65kA at 240V, 35kA at 480V, 18kA at 600V.
Common Applications
- Feeder and branch protection in commercial and industrial panels
- Direct replacement for existing H-Frame MicroLogic breakers
- Circuits that need ground-fault protection built into the breaker
- Full continuous-load feeders where an 80% breaker won't cut it
- Motor and HACR equipment feeds
Key Features
- MicroLogic 6.2A trip: Field-adjustable LSIG protection with an on-board ammeter.
- 100% rated: Run it at full nameplate continuously, no derate.
- Drops right in: Unit mount with line and load lugs; reverse-feed capable.
- Tough interrupting: 65kA@240V, 35kA@480V, 18kA@600V.
- Push-to-trip + Visi-Trip: Manual trip check and clear fault indication.
Specifications
- Manufacturer: Square D by Schneider Electric
- Part Number: HGL36100CU44X
- Frame: PowerPact H-Frame
- Amperage: 100A
- Poles: 3-pole, 3-phase
- Voltage: 600VAC (250VDC rated)
- Trip Unit: MicroLogic 6.2A electronic, LSIG + ammeter
- Continuous Rating: 100%
- AIC: 65kA@240V / 35kA@480V / 18kA@600V / 20kA@250VDC
- Lugs: Line and load, AWG 14–3/0 Al/Cu
- Mounting: Unit mount
- Listings: UL 489, CSA, NEMA, NOM, IEC 60947-2, CE
- HACR Rated: Yes
Product Identification
- Country of Origin: Mexico
- Dimensions: 6.4 in H × 4.12 in W × 4.36 in D
- Net Weight: 4.8 lb
FAQ
Will this drop into my H-Frame panel? Yes — it's a unit-mount H-Frame breaker with standard line and load lugs.
Can I reverse-feed it? Yes, the HGL36100CU44X is suitable for reverse-fed applications.
Does it have ground-fault protection? Yes. The MicroLogic 6.2A is a full LSIG trip unit, so ground fault is built in.
What's the interrupting rating? 65kA at 240V, 35kA at 480V, and 18kA at 600V.
Electronic or thermal-magnetic? Electronic. The CU44X build is MicroLogic 6.2A and 100% rated, not the thermal-magnetic HGL36100.
What wire does it land? AWG 14–3/0 aluminum or copper on the standard lugs.