General Electric
General Electric THK4V4610AG Molded Case Circuit Breaker | 600V 1000A 3P 50kA@480V Bolt-On MicroVersaTrip
General Electric THK4V4610AG Molded Case Circuit Breaker | 600V 1000A 3P 50kA@480V Bolt-On MicroVersaTrip
Out of stock
Couldn't load pickup availability
ABB / GE Branding Notice
On June 30, 2018, ABB completed the acquisition of GE Industrial Solutions. Because of this transition, some products may be labeled as either ABB or GE depending on the manufacturing date and production batch.
Customers may receive products with:
- ABB branding
- GE branding
- Packaging reflecting either brand
Unless otherwise stated, these are considered the same product and are fully interchangeable under the applicable manufacturer specifications.
Please contact our support team before ordering if you have questions about labeling, compatibility, or product identification.
The General Electric THK4V4610AG is a Molded Case Circuit Breaker from the MicroVersaTrip family. It features a 3-pole design with a 600V rating and 1000A capacity, offering solid-state protection. This bolt-on circuit breaker has an AIC rating of 50kA@480V for reliable performance.
Key Features:
✔ Part Number: THK4V4610AG
✔ Manufacturer: General Electric
✔ Category: Circuit Breaker
✔ Subcategory: Molded Case
✔ Family: MicroVersaTrip
✔ Type: THK4V
✔ Voltage: 600
✔ Amperage: 1000
✔ Phase: 3
✔ Poles: 3
✔ AIC rating: 50kA@480V
✔ Connection: Bolt-On
✔ Functions: LIG - Long-Time, Instantaneous and Ground Fault
✔ Protection: Solid State
✔ Weight: 50
Share

- Accessories
- Related Products
| Part | Manufacturer | Sub Category |
|---|---|---|
| tvas2ab2rs | General Electric | Auxiliary |
| 192a702p567 | General Electric | Trip Units & Programmers |
| Part | Manufacturer | Voltage | Amperage | Phase | AIC | Connection | Poles | Functions |
|---|---|---|---|---|---|---|---|---|
| thk4v4604 | General Electric | 600V | 400 | 3 | 50kA@480V | Bolt-On | 3 | LI - Long-Time and Instantaneous |
| thk4v4604n | General Electric | 600V | 400 | 3 | 50kA@480V | Bolt-On | 3 | LSI - Long-Time, Short-Time and Instantaneous |
| thk4v4604ng | General Electric | 600V | 400 | 3 | 50kA@480V | Bolt-On | 3 | LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault |
| thk4v4604wl | General Electric | 600V | 400 | 3 | 50kA@480V | Feed-Thru | 3 | LI - Long-Time and Instantaneous |
| thk4v4606 | General Electric | 600V | 600 | 3 | 50kA@480V | Bolt-On | 3 | LI - Long-Time and Instantaneous |
| thk4v4606n | General Electric | 600V | 600 | 3 | 50kA@480V | Bolt-On | 3 | LSI - Long-Time, Short-Time and Instantaneous |
| thk4v4606ng | General Electric | 600V | 600 | 3 | 50kA@480V | Bolt-On | 3 | LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault |
| thk4v4606wl | General Electric | 600V | 600 | 3 | 50kA@480V | Feed-Thru | 3 | LI - Long-Time and Instantaneous |
| thk4v4608 | General Electric | 600V | 800 | 3 | 50kA@480V | Bolt-On | 3 | LI - Long-Time and Instantaneous |
| thk4v4608a | General Electric | 600V | 800 | 3 | 50kA@480V | Bolt-On | 3 | LI - Long-Time and Instantaneous |